EntelliGuard G
Instruction sheet
4
.4
4.4.10
IP54 Cover
Each EntelliGuard breaker is supplied with a
Door Frame that provides the installed device
with an IP40 rating. Optionally an extra cover is
available providing an IP54 rating.
It can be fitted on the panel door in place of the
door flange. It uses the same hole pattern as
door flange and doesn't require any additional
holes.
Use the following procedure to install the IP54
cover on the panel door.
1. Check that the package contains all the parts
listed in Table.
2. Turn the breaker off and discharge the
closing springs by depressing the OFF and ON
buttons in the sequence OFF-ON-OFF.
Verify that the breaker OFF-ON indicator shows
OFF on a green background and that the charge
indicator shows DISCHARGE on a white
background.
3. Open the panel door. Remove the door flange
from the door by removing the screws from
inside of the door.
4. Assemble the IP54 cover assembly on the
door with screws and washers as shown in
picture.
5. 12 screws are required to assemble the IP54
cover for a drawout type of breaker.
6. 10 screws are required to assemble the IP54
cover for a fixed type of breaker.
Table: Part list
Description:
------------------------------------------------------------
A
Cover Assembly
M4 Hex nut
B
Screws M4 x 10
.... Plain washer M4
.... Lock washer M4
C
Mounting bracket
4.4-16
ACCESSORIES
Folha de Instruções
4.4.10 Tampa de porta IP54
Cada disjuntor EntelliGuard é fornecido com um
aro de remate que proporciona ao dispositivo
instalado um valor de protecção IP40. De forma
opcional, existe uma tampa de porta adicional
que oferece um valor de protecção IP54.
Pode-se montar na porta do armário em
substituição do aro de remate. Utiliza os
mesmos furos que o aro de remate e não são
necessários furos adicionais.
Para instalar a tampa de porta IP54, utilize o
seguinte procedimento:
1. Comprove que a embalagem contem todos
os componentes listados na Tabela.
2. Abra o disjuntor (OFF) e descarregue as molas
principais pressionando os botões OFF e ON
como indicado na sequência seguinte OFF-ON-
OFF.
Verifique que o indicador OFF-ON está em OFF
(fundo verde) e que o indicador de carga de
molas está em DESCARREGADO (fundo branco).
1
3. Abra a porta do armário. Desmonte o aro de
remate retirando os parafusos do interior da
porta.
4. Monte a tampa de porta IP54 na porta com
os parafusos e anilhas, como se indica na foto.
5. Para disjuntores de execução extraível, são
necessários 12 parafusos para montar a tampa
de porta IP54.
6. Para disjuntores de execução fixa, são
necessários 10 parafusos para montar a tampa
de porta IP54.
Tabela: Lista de componentes
Quantity
Descrição
----------------------------------------------------------
A
1
Conjunto de tampa
2
Porca Hex. M4
B
12
Parafusos M4 x 10
12
.... Anilha plana M4
12
.... Anilha de segurança M4
C
1
Suporte de montagem 1
Hoja de instrucciones
4.4.10 Tapa de puerta IP54
Cada interruptor automático EntelliGuard se
proporciona con un marco embellecedor que
proporciona al dispositivo instalado un valor de
protección IP40. De forma opcional, existe una
tapa de puerta adicional que ofrece un valor de
protección IP54.
Se puede montar en la puerta del armario en
sustitución del marco embellecdor. Utiliza los
mismos agujeros que el marco embellecedor y
no se necesitan taladros adicionales.
Para instalar la tapa de puerta IP54, utilice el
siguiente procedimiento:
1. Compruebre que el embalaje contiene todos
los componentes listados en la Tabla.
2. Abra el interruptor (OFF) y descargue los
muelles principales pulsando los pulsadores OFF
y ON según la secuencia siguiente OFF-ON-OFF.
Verifique que el indicador OFF-ON está en OFF
(fondo verde) y que el indicador de carga de
muelles está en DESCARGADO (fondo blanco).
Catalogue Numbers |
-----------------------------------------------------------------------------------
3. Abra la puerta del armario. Desmonte el
marco embellecedor quitando los tornillos desde
el interior de la puerta.
4. Monte la tapa de puerta IP54 en la puerta con
los tornillos y arandelas, como se indica en la
foto.
5. Para interruptores con ejecución seccionable,
se necesitan 12 tornillos para montar la tapa de
puerta IP54
6. Para interruptores con ejecución fija, se
necesitan 10 tornillos para montar la tapa de
puerta IP54.
Tabla: Lista de componentes
Quantidade
Descripción
----------------------------------------------------------
A
1
Conjunto de tapa
2
Tuerca Hex. M4
B
12
Tornillos M4 x 10
12
.... Arandela plana M4
12
.... Arandela de seguridad M4
C
Soporte de montaje
Referencias | Referencias de catálogo
IP54 Cover
G54DR
IP54
G54DR
Tapa de puerta
IP54
G54DR
Cantidad
1
2
12
12
12
1