Kenmore 75855 Manual De Uso Y Cuidado página 44

Idiomas disponibles

Idiomas disponibles

Converting to LP Gas (continued)
Step
6
Check for Leaks
When all connections
have been made, make sure all
range controls
are in the off position
and turn on the
main
gas supply
valve,
Use a liquid leak
detector
at all joints and connections
to check for leaks in the
system°
CAUTION:
DO NOT USE A FLAME TO CHECK
FOR GAS LEAKS.
When
using test pressures
greater
than
1/2 psig to
pressure
test the gas supply system
of the residence,
disconnect
the
range
and individual
shut-off
valve
from the gas supply
piping.
When
using
test pres_
sures
of 1/2 psig or less to test the gas supply
sys-
tem,
simply
isolate the range
from the gas supply
system
by closing the individual shut-off valve.
Step
?
Convert Top Burner VaJves
NOTE:
Only
valves
with
these
types
of knobs
are
adjustable
Step
8
Check QuaJib] of Flames
The combustion
quality
of burner flames
needs to be
determined
visually.
(A) Yellow flames--
Call for service
(B) Yellow
tips on outer
cones--Normal
for
LP gas
(C) Soft blue flames--
Normal for natural gas
If burner flames
look like (A), call for service
Normal
burner flames
should
look like (B) or (C), depending
on the type of gas you user
With LP gas, some yellow
tipping
on outer
cones is
normal
1. Turn alf of the top burners
to LOW°
2, Remove
all 4 knobs,
3oWith
a small
flat
screwdriver,
turn
the
valve
set screws
clock-
wise
to decrease
flame
size, counterclockwise
to
increase
flame
size_
Adjust
until the flame
is
about the same height as
the top of the burner,
4. Replace
the knobs..
5. Check for flame outage
by opening
and closing the
oven
door
several
times.
If the flame
goes
out,
increase the flame size.