Bosch EPS 205 Manual Original página 40

Ocultar thumbs Ver también para EPS 205:
Idiomas disponibles

Idiomas disponibles

en
40 | EPS 205 | Maintenance
8.2.9
Checking toothed belt
The condition and tension of the toothed belt can only
be checked by Customer service personnel.
The toothed belt is to be replaced if checking reveals
the following signs of damage:
R
Toothed belt torn or not intact
R
Corroded wire inlays in toothed belt
R
Severely worn tooth flanks
8.2.10
Replacing toothed belt
The toothed belt is only to be replaced by Customer
service personnel.
8.2.11
Replacing inlet filter element
i
Dirt deposits in the inlet filter are primarily the
result of common rail injectors not having been
cleaned, or only inadequately, before testing.
458846-24_Ko
6
5
4
Abb. 46: Replacing filter element
1 Screw connection
2 Flat sealing ring
3 Spring
4 Filter element
5 O-ring
6 Screw connection
1. Detach the inlet filter from the quick-release cou-
plings.
2. Use two wrenches to slacken off and completely
open up the screw connections (Fig. 46, item 1
and 6).
3. Take out the flat sealing ring, spring, filter element
and O-ring (Fig. 46, item 2, 3, 4, 5).
4. Take out and dispose of the flat sealing ring, filter
element and O-ring.
5. Clean both screw connections with clean test oil.
6. Fit a new O-ring.
7. Fit a new filter element in the correct position.
8. Fit a new flat sealing ring.
9. Insert the spring.
10. Fasten the screw connections and tighten with
a torque wrench (tightening torque = 50 Nm).
"
This completes filter element replacement.
|
1 689 989 186
2017-10-27
3
2
1
8.2.12
Replacing the strainer of the changeover
valve
DANGER - Risk of electric shock from live
parts!
Contact with live parts (e.g. master switch,
printed circuit boards) in open devices can
cause electric shock, heart failure and fatal-
ity.
After switching the device off, allow parts
a period of one minute to discharge.
Procedure:
1. Switch off the EPS 205.
2. Disconnect EPS 205 from the three-phase system.
4
Abb. 47: Removing the housing cover
1 Ground cable
2 Fastening screws (8 x)
3 Housing cover
4 Changeover valve with strainer bracket
3. Unscrew the right housing fastening screws (8x)
(fig. 47, item 2).
4. Detach the housing cover (fig. 47, item 3).
5. Unscrew the ground cable from the housing cover
(fig. 47, item 1).
1
2
3
Robert Bosch GmbH
loading