22 | EPS 205 | Product description
5.6.16
Return adapter accessory set 1 687 016 038
The return adapter accessory set is needed for CRIN
with split return quantity.
4
3
5
Abb. 27: Fitting return adapter
1. Screw the plug-in nipple (Fig. 27, item 1) with flat
sealing ring (10.2 x 13.4 mm) into the distributor
head (Fig. 27, item 2) and secure.
2. Screw the hose connection (Fig. 27, item 3) with flat
sealing ring (10.2 x 13.4 mm) into the end face of
the distributor head and secure.
3. Attach both hoses (Fig. 27, item 4) to the hose con-
nections and secure with two hose clamps (Fig. 27,
item 5).
4. Fit the other two hose clamps on the other end of
the hoses.
Connection of return adapter for CRIN with split
return quantity
Abb. 28: Connection of return adapter
|
1 689 989 186
2017-10-27
1
2
3
4
5
Connecting return adapter to connection panel
X20
1
3
4
Abb. 29: Connecting return adapter to connection panel
1 EPS 205 connection panel
2 Hose 1 680 712 360
3 Return adapter
4 CRIN
Return adapter with threaded connection
For CRIN with screw connection M8 x 1.
3
Abb. 30: Fitting return adapter with threaded connection
Screw the plug-in nipple (Fig. 30, item 1) and
adapter (Fig. 30, item 3) with flat sealing ring
10.2 x 13.4 mm (Fig. 30, item 2) together and se-
cure.
2
Robert Bosch GmbH