Software Features; Programming Mode; Dimensions And Installation; Electrical Wirings - Pixsys ATR244-12ABC Manual De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3.3

Software Features

Regulation algorithms
Proportional band
Integral time
Derivative time
Controller functions
3.4

Programming mode

by keyboard
software LabSoftview
App MyPixsys
4

Dimensions and Installation

Dima di foratura
46 x 46 mm
Frontal panel
cut-out
T
rou de panneau
Spessore suggerito / Suggested thickness / É
5

Electrical wirings

This controller has been designed and manufactured in conformity to Low Voltage Directive 2006/95/
EC, 2014/35/EU (LVD) and EMC Directive 2004/108/EC, 2014/30/EU (EMC). For installation in industrial
environments please observe following safety guidelines:
• Separate control line from power wires.
• Avoid proximity of remote control switches, electromagnetic contactors, powerful engines.
• Avoid proximity of power groups, especially those with phase control.
• It is strongly recommended to install adequate mains filter on power supply of the machine where
the controller is installed, particularly if supplied 230Vac.
The controller is designed and conceived to be incorporated into other machines, therefore CE
marking on the controller does not exempt the manufacturer of machines from safety and conformity
requirements applying to the machine itself.
• Wiring of pins 1...8 on ATR244-12ABC, ATR244-12ABC-T or ATR244-13ABC: use crimped tube
terminals or flexible/rigid copper wire with diameter 0.2 to 2.5 mm2 (min. AWG28, max. AWG12,
ON-OFF with hysteresis. - P, PI, PID, PD with proportional time
0..9999°C o °F
0,0..999,9 sec (0 excludes)
0,0..999,9 sec (0 excludes)
Manual or automatic Tuning, selectable alarm, protection of command
and alarm setpoints.
..see paragraph
12
..on "Download section" of official pixsys site: www.pixsys.net
..through download the App on Google Play Store®, see paragraph
When activated by a reader/interrogator supporting NFC-V protocol,
controller ATR244 is to be considered a VICC (Vicinity Inductively
Coupled Card) according to ISO/IEC 15693 and it operates at a frequency
of 13.56 MHz. The device does not intentionally emit radio waves.
C1
C2
A1
A2
A3
TUN
MAN
FNC
48 mm
paisseur suggérée
Memory Card USB
(optional)
Cod. 2100.30.013
ATR244
REM
SET
8
2
USB
80 mm
÷ 6
mm
User manual - ATR244 - 11