Pixsys ATR244-12ABC Manual De Instalación página 59

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

217 A.6.o.t.
Alarm 6 Output Type
Defines the output type if the alarm 6 is analogue.
Output 0...10 V. Default
0.10 v
Output 4...20 mA.
4.20ma
218 a.6.Hy.
Alarm 6 Hysteresis
Alarm 6 hysteresis
-9999..+9999 [digit
219 A.6.L.L.
Alarm 6 Lower Limit
Lower limit selectable for the alarm 6 setpoint.
-9999..+30000 [digit
220 A.6.u.L.
Alarm 6 Upper Limit
Upper limit selectable for the alarm 6 setpoint.
-9999..+30000 [digit
221 a.6.re.
Alarm 6 Reset
Alarm 6 contact reset type (always automatic if
Automatic reset (Default)
A. rEs.
Manual reset (manual reset by keyboard or by digital input)
M. rEs.
Stored manual reset (keeps the output status also after a power failure)
M.rEs.S.
Automatic reset with timed activation. The alarm remains active for the time set on the
A. rEs.t.
parameter 224
again, the alarm conditions must disappear.
222 A.6.S.e.
Alarm 6 State Error
Alarm 6 output status in case of error.
If the alarm output is 0-10V:
0 V. Default
0 V
If the alarm output is 0-20 mA or 4-20 mA:
0 mA. Default
0 ma
4 mA.
4 ma
223 rES.
Reserved
Reserved parameter
224 a.6.de.
Alarm 6 Delay
Alarm 6 Delay.
-60:00..60:00 mm:ss (hh:mm if
Negative value: delay when exit alarm status
Positive value: delay when enter alarm status
225 A.6.S.p.
Alarm 6 Setpoint Protection
Allows or not to change the alarm 6 setpoint.
Editable by the user (Default)
FrEE
Protected
Lock
Protected and not visualized
HidE
226 A.6.Lb.
Alarm 6 Label
Selects the message displayed in case of alarm 6 intervention.
Disabled. (Default) 0.
disab.
Message 1 (see table on paragraph 14.1) ..
lb. 01
Message 20 (see table on paragraph 14.1)
lb. 20
Custom message (modifiable by the user through the App or via modbus)
user.l.
] (degrees.tenths for temp. sensors). Default 0.5.
1 p. 74
] (degrees for temp. sensors). Default 0.
1 p. 74
] (degrees for temp. sensors). Default 1750.
1 p. 74
, even if the conditions generating it are missing. To be able to act
a.6.de.
=
AL.6.F .
=
AL.6.F .
c. Aux
10 v
20 ma
21.5ma
). Default: 00:00.
c. aux
).
10 V.
20 mA.
21.5 mA.
User manual - ATR244 - 59

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Atr244-12abc-tAtr244-13abcAtr244-23a-tAtr244-23bc-t

Tabla de contenido