Nogueira EXPRESS-5040 Manual De Instrucciones página 54

Ocultar thumbs Ver también para EXPRESS-5040:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ATTENTION!
If the measure B is higher than recommended (140mm), the needles support
will hit the pressing chamber when the needles go up to the knotter, damaging
the support. Keep measure B between 135 to 140mm.
54
DISC
Measure B = Distance from the needle
tip from the disk = 135 to 140mm.
PRESSING CHAMBER
Instructions Manual
NEEDLE
B
NEEDLES SUPPORT
fig. 91
fig. 92

Capítulos

Tabla de contenido
loading

Tabla de contenido