3- Remove the cotter pin and disassemble the pin B.
CARE! If the safety bolt is broken, the arm C is loose, and upon removing the
pin B it goes down.
4- Remove the broken end of the safety bolt, which may be in the point of the
arm C.
5- Assemble the arm C within the tube D.
6- Place a new safety bolt.
7- Replace the pin B.
fig. 57
IMPORTANT!
SAFETY BOLT OF THE COLLECTOR (A):
Located on the flange of the cardan of the collector shaft, if there is an overload
on the collection, caused by excessive feeding or by the presence of a foreign
body, the safety bolt breaks, immediately stopping the collection.
If this occurs, replace the broken bolt and eliminate the reason for it breaking.
Verify that the collector is not obstruced and that the collecting springs are in
good condition. Replace twisted or broken springs.
42
fig. 58
In order to ensure safety and the perfect functioning of
the device, only use genuine pins.
See that the needles are in a perfect state. Replace them
if they are damaged.
During the adjustment, be careful not to move the nut
F from its position, as this will affect the synchronism of
the needles with the piston.
Instructions Manual
D
F
R
C
A
fig. 59