SUPER TOP
Installation and connections
3.4.b - Unipotential connection (Fig 6)
The equipment shall be inserted in a unipotential system,
whose effectiveness shall be verified according to the
rules being in force.
Remove the cover (1) by undoing the screws (2) (Fig. 5).
A cascade connection shall be carried out among the
various oven components by using the screw (3) placed
on the rear oven side.
3.5 - OVEN POSITIONING (Fig 7)
DANGER
The oven shall NOT be installed closed to
inflammable walls such as furniture, parti-
tion walls, matchboarded coatings etc...
A safety range of at least 50 mm from lateral
and rear oven sides should be kept.
No inflammable flooring shall be utilized to
install the oven on it.
IMPORTANT
In case the oven shall be built in, there
shall be a suitable change of air on its rear
side and this can be obtained by means of
air grilles (1) placed on the wall.
• The oven shall be positioned on the final area follow-
ing the indications reported in figure 7, because they
indicate the minimum distances required to allow the
oven correctly to function.
• Fix the oven position by braking the rear wheels.
50 mm
FIG. 6
1
50 mm
1
3
2
1
1
1
2
EN - 15