3.3.b - Electric hood connection
Concerning electric hood connection, follow the
instructions supplied with the hood.
3.3.c - Unipotential connection (Fig 7)
The equipment shall be inserted in a unipotential system,
whose effectiveness shall be verified according to the
rules being in force.
A cascade connection shall be carried out among the
various oven components by using the screw (1) placed
on the rear oven side.
3.4 - OVEN POSITIONING (Fig 8)
The oven shall not be installed closed to inflammable
walls such as furniture, partition walls,
matchboarded coatings etc... A safety range of at
least 20 cms from lateral and rear oven sides should
be kept. No inflammable flooring shall be utilized to
install the oven on it.
• The oven shall be positioned on the final area following
the indications reported in figure 8, because they indi-
cate the minimum distances required to allow the oven
correctly to function.
• Fix the oven position by braking the rear wheels.
3.4.a - Chimney connection (Fig 9)
•
Place the fitting (2) on the chimney (1).
•
Connect the Ø 100 mm fitting (2) with a natural
draught conduit or a hood.
3.5 - FIRST STARTING
Once the oven is installed and before starting it,
carefully clean its inner part as well as refractory
surface as explained in "Maintenance" chapter, also
make sure neither foreign nor inflammable bodies
are inside the oven.
• Star t the oven as prescribed in "Functioning"
paragraph, making sure the set temperature is
correctly reached and the different options (according
to the concerned model) properly function.
GB - 14
DANGER
DANGER
MILLENNIUM MM/MB
Installation and connections
FIG. 7
1
FIG. 8
200 mm
200 mm
FIG. 9
2
1
90