Electrical System; Hydraulic Circuit - BCS VALIANT 400 Manual De Uso

Tabla de contenido
the.engine.fails.to.reach.its.maximum.power
Call the Lombardini assistance service if you are unable to find the cause of a fault.
ELECTRICAL sysTEM
Fault
no.current.in.the.electrical.circuit
the.battery.fails.to.recharge.(red.alternator.
indicator.light.on.with.the.engine.running)
Call your area dealer if you are unable to find the cause of a fault.

hyDRAULIC CIRCUIT

Fault
the.hydraulic.circuit.fails.to.function.correctly
the.hydraulic.oil.overheats
Call your area dealer if you are unable to find the cause of a fault.
GB
engine.overloaded
air.filter.clogged
Implement.badly.regulated
Cause
main.fuse.damaged
discharged.battery
tarnished.battery.terminals
Worn.or.loosened.alternator.belt
Faulty.alternator
Faulty.electrical.system
Faulty.battery
Cause
oil.level.low
oil.filter.element.clogged
Faulty.hydraulic.circuit
oil.level.too.high.or.low
oil.filter.element.clogged
Faulty.hydraulic.control.valves
engage.a.lower.gear.or.reduce.the.load
clean.the.air.filter
consult.the.implement.instruction.manual
Remedy
replace.the.fuse
recharge.or.replace.the.battery
clean.the.terminals.and.smear.vaseline.grease.
over.them
check.the.belt.stretcher..replace.the.belt.if.worn
contact.your.area.dealer
contact.your.area.dealer
replace.the.battery
Remedy
top.up.the.circuit
replace.the.filter
contact.your.area.dealer
top.up.the.oil.level
replace.the.filter
contact.your.area.dealer