- Perform a second spin.
- At the end of the spin, change the position of the calibration weight on the swinging
unit bell as indicated in figure 19.
- Perform a third spin.
This last calibration phase includes the execution of three consecutive spins in au-
tomatic mode.
At the end of the spin (the message "End CAL" will appear on the display), if the cali-
bration has been successful, an acoustic consent signal goes off at the end of the spin
otherwise the message E 2 is temporarily displayed.
NOTES
- Once the procedure is finished, remove the calibration weight.
- Pressing the key
- THE CALIBRATION DESCRIBED ABOVE IS VALID FOR ANY TYPE OF WHEEL!
94
, it is possible to interrupt the programme at any time.
19
EM 7240 Operator's manual