- Move the end of the automatic measuring arm in line with the plane selected for the
application of the inner weight. ). In Alu 1 P, the centre of the pawl on the end section
of the lever is taken as a reference for the centre line of the weight (version without the
weight holding device). In versions with the weight holding device, the centre line of the
weight must correspond with the centre of the groove in which the weight will be placed.
(Fig. 13/13a)
- In Alu 2 P refer to the rim edge, since the inner weight is of the traditional clip type
(Fig. 10/10a).
Pay maximum attention when the end of the arm is being placed in an area of the
rim free of discontinuity, so that the weight can be applied in that position.
- Keep the arm in position. After two seconds the machine emits an acoustic confirmation
signal to indicate that the distance and diameter values have been acquired.
- Move the end of the automatic measuring arm in correspondence with the plane selected
for the application of the outside balancing weight (Fig. 14/14a), in the same manner as
described previously for the inner side.
82
13
14
13A
14a
EM 7240 Operator's manual