UNBALANCE DISPLAY IN GRAMS/OUNCES
The setting for the display of the unbalance values in grammes or ounces is made by
keeping the key
When started up, the machine is set to display the unbalance values at five-gramme
increments, i.e. rounded to the nearest multiple of five (or quarters of an ounce if visu-
alised in ounces).
In this condition, the first four grams of unbalance are not displayed since an appropriate
threshold, indicated by illumination of the
The
key can be pressed to eliminate the threshold (the illuminated indication
"x5"; "oz/4" goes out) and the unbalance values will be displayed gram by gram (or in
tenths of an ounce if display in ounces is active).
Pressing the button consecutively allows the user to set one visualisation mode or the other.
Press the
key on the display together with the button on the left side
and hold them down until the braking phase starts. If one of the two contacts,
or both, is released during the wheel start-up or reading phase, the message
"A Cr" will appear and the brake will be automatically activated.
WARNING
Do not operate the machine if the safety device has been tampered with.
WARNING
During machine use, personnel may not be present in the area enclosed by the sec-
tioning in Fig. 5a.
EM 7240 Operator's manual
pressed for about five seconds.
ROUNDING-OFF
WHEEL SPIN
LED on the display panel, is activated.