Continuous Timed Cycle
This cycle can be used when large quantities
of food are to be chilled and the specific chilling
time of each product is known. Just set the cell
temperature, the fan speed and start the machine.
The appliance maintains the set temperature, the
defrosting is automatically managed. The cell
temperature can be changed during the normal
operation.
By selecting the continuous timed cycle the system
will propose following screenshot :
By pressing the area
possible to change the operating cell temperature.
By pressing the area
possible to change the fan speed.
To confirm the new settings press the
on the right bottom : the cycle will start.
During a current cycle, following screenshot will be
displayed :
Number of the current phase
The cycle starts only by activating the first timer; it
is possible to set up to three different timers.
Timers can be set by pressing the pencil area and
setting the time while the cycle is running.
When setting the time, once the timer is confirmed,
its count starts directly.
Each timer is independent and can be reset at its
completion.
it is
The cycle ends when all set timers have expired.
At the end of a timer count, the buzzer sounds, the
display shows a message and the value "0 min "of
it is
the corresponding timer is displayed in green.
area
Pressing on the area
temperatures detected by the various probes, the
state of inputs / outputs and the alarms stored by
the system. To abort the current cycle press for at
least three seconds the area