8.4.
Extraordinary Maintenance (5T Version)
Cleaning the evaporator
Clean the evaporator periodically.
!
As the fins of the evaporator are very sharp,
always wear protective gloves for the next
phases. Only a brush must be used for cleaning:
do not use jets of liquid or sharp instruments.
To access the evaporator proceed as follows:
1. Open the door (A) of the appliance.
2. Loosen the two screws (B) on the right of the
deflector.
3. Remove the runners (C):
4. Turn the deflector (D) to the left
C
B
C
U.V. Lamp Replacement
After having removed the flush sliders, remove the
screws that fix the evaporator deflector onto the
right side (A).
A
A
C
C
B
D
Once you have removed the screws, the
evaporator deflector can be opened by turning it.
Access the UV lamp. This lamp can be removed by
sliding it upwards (B). Carry out all the operations
in reverse order after having removed the U lamp.