Description
Torque
Display accuracy
Display resolution [N m]
Setting resolution [N m]
Overload limit
Angle
Size 1
Display
accuracy
Display
resolution
Setting
resolution
Min. angle
rate
Max. angle
rate
Angle
Display accuracy
Display resolution
Setting resolution
Min. angle rate
Max. angle rate
Tolerances
Lower tolerance limit
Upper tolerance limit
Size 65
1
1
Size 2
Size 4
Size 65
Adjustable:
No tolerance
Relative tolerance
Absolute tolerance
Max. 100 % of the target, but at least 80 % of the initial measuring range
value
Max. 100 % of the target, but at least 120 % of the initial measuring
range value
Size 80
±2 %
±1 digit
1
2
125 %
Size 6
Size 10
±1 % ±1 digit
0.1°
1°
≤1.2°/s
≤180°/s
Size 80
±2 %
±1 digit
0,1°
1°
≤1,2°/s
≤180°/s
Size 100
1
2
Size 20
Size 40
Size 100
19