Undertaking settings on the PC
Undertaking settings on the
PC
If the torque and angle wrench is connected to a
PC, the SENSOMASTER software can be used
e.g. to exchange data between the torque and
angle wrench and the PC.
Various settings can also be changed on the PC.
The settings are then transferred to the torque and
angle wrench.
For information on operation of the
SENSOMASTER software, refer to the relevant
online help.
The following settings can be undertaken on the PC
and transferred to the torque and angle wrench:
Set units
Assign an ID
Set a time for the torque and angle wrench to
switch off automatically
Set an alert limit
Define a calibration date
Assign an administrator password
Transfer the fastener data available in the internal
torque and angle wrench memory to a PC
Delete the internal torque and angle wrench
memory
Define sequence plans
Define bolting operations
Set a menu language
Configure menus
Prerequisites for connection to a PC include:
A USB interface,
Microsoft Windows,
A micro USB cable and
The installed SENSOMASTER software.
40
ATTENTION
Malfunctions possible.
Insert the micro USB connector to
stop into the socket in one
movement.
Make sure that the connectors are
firmly seated.
Connecting the torque and angle
wrench to the PC
Make sure that the torque and angle wrench is
switched off.
Fold the PC connection socket cover to the side.
Insert the micro USB connector to stop into the
PC connection socket in one movement.
Insert the USB connector into the PC's USB
connection.