ALARM
DESCRIPTION
ALARM 11
PLC communication error
ALARM 12
CAN communication error
ALARM 13
Machine type error
Temperature
ALARM 14
NTC2 (safety)
ALARM 15
Heating error
ALARM 16
Humidity sensor error
ALARM 17
Cooling error
NTC1
ALARM 18
temperature
NTC2
ALARM 19
temperature
Temperature
ALARM 20
between NTC1/NTC2 too great
Difference between the speed
ALARM 21
measured by PLC and the
cylinder speed.
Speed measured by the PLC =
ALARM 22
0
Drive fault: folding machine
ALARM 23
motor
ALARM 24
PDM error (HPS option only)
If one of the alarms persists contact your dealer's technical department.
CAUSE/SOLUTION
The communication between the microprocessor board
(HMI) and the PLC is interrupted or defective. (Folding
machine option only).
Communication between the microprocessor board (HMI)
and the relay board (IOS) is interrupted or defective.
The microprocessor board is not properly configured to
the machine model. A shunt must be present on the
microprocessor board (HMI) CN6 connector - See electric
diagram.
sensor
error
The NTC2 temperature sensor is disconnected or
defective.
The temperature has not increased by 1°C after 60
minutes (value adjustable in the maintenance menu).
The humidity sensor is disconnected or defective.
The temperature has not decreased by 1°C after 60
minutes (value adjustable in the maintenance menu)
during the cooling phase.
sensor
excess
The cylinder temperature is over 205°C
sensor
excess
The cylinder temperature is over 205°C
difference
The temperature difference between the NTC1 and NTC2
sensors is greater than 50°C
The cylinder speed is different from that measured by the
PLC using the incremental encoder. (Folding machine
option only).
The speed measured by the PLC using the encoder is
equal to 0. (Folding machine option only).
The folding motor drive is defective (visible on the variable
drive display). Check the folder motor. (Folding machine
option only).
The PDM photoelectric cell (at laundry infeed) is defective
or the beam is not reflected for a certain time (HPS only).
48