4.2.
Opening the top panels
To open the top panels, remove all screws on the top and back of the machine and the small
centre plate.
To keep the top panel open, a rod is available inside it, slide it to the right to raise it and keep
the top panel open. The rod must be placed vertically to block it mechanically and allow safe
working.
To close the top panel, lift it slightly to release the rod, pull the rod up to mechanically unlock
it and tilt it to the left before closing the top panels
Rod
Slide the rod to the right
4.3.
Replacing the guide bands
Guide bands are used to prevent the laundry from wrapping around the pressing roller.
Therefore regular checks should be made to make sure that there are no missing guide bands.
Their presence is essential.
The guide band reference is 12156329 (supplied per metre).
To access the guide bands, raise the top panels (see section 4.2).
Position it vertically under the top
panel
Guide bands placed along the
entire length of the machine.
Band guide