Gas nature
Supply pressure (mbar)
Machine type
Injector mark
Air adjustment "d" (mm)
Burner flow (m³/hour)
Power (KW)
Gas type
Supply pressure (mbar)
Machine type
Injector mark
Air adjustment "d" (mm)
Burner flow (Kg/h)
Power (KW)
2.2.5.2 Radiant burner (PS-50 TP2 option) - GR
This type of burner is standard on PS-65 TP2 models.
The GAS connection is on the right part of the machine. The GAS connection diameter is 1/2''
(15/21 mm). The gas supply hose (not supplied) must pass through the back of the machine
through one of the holes in the frame.
G20
20
PS-
PS-
PS-
50/200
50/260
50/330
4.7
5.5
6.2
18
18
18
4.2
5.8
7.3
40
55
69
G31
37
PS-
PS-
PS-
50/200
50/260
50/330
3.2
3.7
4.1
18
18
18
3.1
4.3
5.6
40
55
69
Used to adjust the air setting "d"
Injector location
GAS connection
G25
20
PS-
PS-
PS-
50/200
50/260
50/330
5.1
6.2
6.9
0
0
0
4.9
6.8
8.5
40
55
69
G31
50
PS-
PS-
PS-
50/200
50/260
50/330
3
3.4
3.8
18
18
18
3.1
4.3
5.6
40
55
69
Distance "d" depending
on the nature and type of
GAS
G25
25
PS-
PS-
PS-
50/200
50/260
50/330
4.9
5.8
6.5
0
0
0
4.9
6.8
8.5
40
55
69
15