Fagor PS-50/200 TP2 Manual De Instrucciones página 16

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
2.2.4. Connection to the electricity supply
The electricity supply cable is not included.
The machine must be connected to the electricity supply using an electric cable that has the
specifications defined in the tables below and protected by a 300 mA or 30 mA SI (super
immunised) ground fault circuit breaker. The electric cable must not be connected to a plug
and at least 50 cm of slack must be left in the machine to connect the cable directly to the cut-
off switch in the machine.
The electric installation must comply with applicable standards. Make sure the supply voltage
matches the technical data on the identification plate located behind the machine (see section
2.1).
It is essential that the earth be properly connected to guarantee user safety and proper
operation.
Motor power (KW)
Heating power (KW)
Total power (KW)
Supply voltage
400V 3P + N + E
Protection
(A)
230V 3P + E
400V 3P + N + E
Cable size
(mm²)
230V 3P + E
The power cable must be connected to the cut-
off switch in the left frame. The power supply
cable must pass through the back of the machine
through one of the holes in the frame as shown
above.
ELECTRIC heating (E)
PS-
PS-
50/200
50/260
0.62
0.87
31.5
40.5
32.12
41.37
63
80
100
125
5G16mm² 5G16mm² 5G25mm² 5G16mm² 5G25mm² 5G25mm²
4G25mm² 4G25mm² 4G35mm² 4G25mm² 4G35mm²
PS-
PS-
50/330
65/200
65/260
0.87
1.05
54
42
54.87
43.05
100
80
160
125
PS-
PS-
65/330
1.05
1.05
54
72
55.05
73.05
100
125
160
N/A
N/A
12
loading