Installation and connection
Connections on underside of device
Fig. 20: Overview of connections on underside of device
6
USB1
7
USB2
8
ETH 0
9
ETH 1
10
RS485/CAN (J1000) (not assigned)
11
Power supply (J102), 24 V (DC)
12
Relay (J900) (not assigned)
13
Relay (J901) (not assigned)
g Refer to chapter "Overview of connectors" on page
46.
46
Installation and connection
Overview of connectors
The overview of device connections ((Fig. 19),
(Fig. 20)) shows the connection position of connec-
tors used for current converters, voltage measure-
ment, relay contacts and communication. The dia-
gram illustrates the position of the pins for each type
of connector. The tables show the pin assignment
with corresponding signal.
g Refer to chapter "Overview of device connections"
on page 45.
Connector for current measurement
Information
It is essential to note the connection positions of the
current converters, the type of current converters,
their phase assignment and the rated current of the
phase fuse, as you will be asked for this information
later on when configuring the energy manager (in-
stallation assistant of the web application).
Parameter
Value
Push-on connector
J200/J300/J301
Manufacturer
Phoenix Contact
Socket part number
1786853
Connector part number
1790124
Overview of J200/J300/J301 connectors
The connectors of the current converters (J200,
J300, J301) are identical and can be connected to
any of the connections provided ((Fig. 19 2/3/4)).
Fig. 21: Overview of J200/J300/J301
Pi
Current converter
n
J200
J300
J301
1
1
5
9
2
1
5
9
3
2
6
10
4
2
6
10
Code
"l",
black
"k",
white
"l",
black
"k",
white