Setting the pace since 1953
11.3.3 - REPLACE THE BLADES
1. Check whether there is sufficient space at the back of the rotary blades vacuum pump
to operate smoothly, otherwise the rotary blades vacuum pump
must be previously dismantled from its support;
2. Remove the back
3. Extract the blades from the rotor;
4. Clean the Rotary blades vacuum pump.
5. Replace the blades and the gasket and the seals of the rear flange;
6. Re-fit the back of the rotary blades vacuum pump
7. Use only Battioni Pagani
Request the rotary blades vacuum pump servicing kit
containing a single blister: Battioni Pagani original blades,
gaskets and original Battioni Pagani
11.3.4 - BLADE DIMENSIONS
MODEL
FAN 420
FAN 530
Table 6
IMPORTANT: Ensure the blades received as replacements are of a length that is less than or equal to the nominal
size indicated by Table 6. Use only Battioni Pagani
11.4 - TECHNICAL SUPPORT
Contact Battioni Pagani® authorised distributors for technical assistance or supply of accessories and spare parts.
Inspection hole
original spare parts
®
seals
®
BLADE NUMBER
Figure 10
5
5
original spare parts
®
Figure 11
BLADE MEASUREMENT
370x60x6.5
460x60x6.5
page 43