The rotary blades vacuum pump of the FANS series were designed and manufactured to allow their use in continuous service, thanks
to a system of forced air cooling via cooling fans.
On request they are equipped with a cooling system for injection of air at room temperature which, after passing through a filter and
overcoming the resistance of a check valve, it enters the side dedicated to compression, decreasing the temperature inside.
The intended use is semi-industrial, suitable for all applications that do not require the exceeding of substantial and consistent
hydrostatic pressure and consequently of a very high degree of vacuum but which require a longer operation time compared to
traditional use.
1 - VERSIONS OF THE FAN ROTARY BLADES VACUUM PUMPS
ROTATION
RIGHT
ROTATION
RIGHT
1.2 - TECHNICAL DATA
Geometrical capacity
m
/h
l/min
3
FAN 420
720
11980
FAN 530
893
14890
page 28
GENERAL INFORMATION
VERSION .../ P (for pulley application)
ROTATION
LEFT
•
UPON
REQUEST
VERSION .../ H (for hydraulic drive)
•
Max rpm
Max abs
pressure
bar/psi
cfm
P/H
423
1500
2.5 (36)
525
1500
2.5 (36)
... / P the power take-off is driven via a pulley and belts. The
version can be recognised by the cylindrical shaft with key of
the power take off and by the plate, ... / P = pulley application.
... / H the power take-off is driven via a gears hydraulic motor.
This version can be recognised by the hydraulic motor support
placed at the front and by the identification plate, ... /H =
hydraulic drive.
Max
Max
continuous
vacuum
vacuum %
% (inHg)
(inHg)
95%
91%
(28.5")
(27")
95%
91%
(28.5")
(27")
Setting the pace since 1953
Power
Weight kg
at max
vacuum
in kW
P
(HP)
23
180
203
(30.8)
27
223
293
(36.1)
H