Safety And Monitoring Devices; Safety Rules During Operation; Pumped Liquids; 2.11. Sound Pressure - salmson Rocsan lix Instalacion Y Puesta En Servicio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
English
The protection class of the installed switching de-
vices can be found on the device housing
and the operation manual.
2.8.

Safety and monitoring devices

Our products can be equipped with mechanical (e.g. intake
strainer) and/or electrical (thermo sensors, moisture sensors, etc.)
safety and monitoring devices. These devices must be attached
and connected.
Electrical devices such as thermo sensors or float switches must
be connected and tested by an electrician before start-up.
Please note that certain devices require a relay to function proper-
ly, for example a PTC thermistor and PT100 sensor. This relay can
be obtained from the manufacturer or an electrical supply dealer.
Personnel must be informed of the systems used and
how they work.
CAUtIoN!
never operate the product if the safety and moni-
toring devices have been removed or damaged, or
if they do not work.
2.9.

Safety rules during operation

When operating the product, always follow the locally applicable
laws and regulations for work safety, accident prevention and
handling electrical machinery. To help to ensure safe working
practice, the responsibilities of employees should be clearly set
out by the owner. All personnel are responsible for ensuring that
regulations are observed.
The product has moving parts. During operation, these parts turn
to pump the fluid. Certain materials in the pumped fluid can cause
very sharp edges to form on the moving parts.
BEWARE of rotating parts!
The rotating parts can crush and sever limbs. never
reach into the hydraulics or the moving parts
during operation.
• Before performing maintenance or repairs, switch
off the product, disconnect it from the mains and
secure it against being switched on again without
authorization.
• Let the moving parts come to a stop!

2.10. Pumped liquids

Each pumped liquid differs in respect of composition, corrosive-
ness, abrasiveness, dry matter content and in many other aspects.
Generally, our products can be used for many applications. Please
note that if requirements change (density, viscosity or general
composition), this can also affect many parameters of the prod-
uct.
When using or replacing the product in a different pumped liquid,
observe the following points:
• The pumped liquid can be contaminated by oil from the
oil separation chamber if the mechanical shaft seal is
defective.
Use in drinking water is not permitted!
All manuals and user guides at all-guides.com

2.11. Sound pressure

Depending on the size and output (kW), the product generates a
sound pressure of approximately 70 dB (A) to 110 dB (A).
The actual sound pressure, however, depends on several factors.
These include the installation depth, configuration, fastening of
accessories and pipeline, operating point, immersion depth, etc.
Once the product has been installed, we recommend that the
operator make additional measurements under all operating
conditions.
3.
3.1.
On delivery, immediately check that the product is complete and
undamaged. If any parts are damaged or missing, the transport
company or the manufacturer must be notified on the day of de-
livery. Claims made after this date cannot be recognized. Damage
to parts must be noted on the delivery or freight documentation.
3.2.
Only the appropriate and approved fastening devices, transpor-
tation and lifting gear may be used. These must have sufficient
load-bearing capacity to ensure that the product can be trans-
ported safety. If chains are used they must be secured against
slipping.
The personnel must be qualified for the tasks and must follow all
applicable national safety regulations during the work.
The product is delivered by the manufacturer or shipping agency
in suitable packaging. This normally precludes the possibility of
damage occurring during transport and storage. The packaging
should be stored in a safe place for reuse if the product is fre-
quently used at different locations.
35
• Products that have been operated in dirty waste water
must be cleaned thoroughly before being used for other
pumped liquids.
• Products that have been operated in sewage water and/or
fluids that are hazardous to health must be decontaminat-
ed before being used with other pumped liquids.
It must be clarified whether the product can be used
at all with another pumped liquid.
• It is strictly prohibited to pump explosive or highly flam-
mable liquids in pure form!
DAnGER - explosive liquids!
It is strictly prohibited to pump explosive liquids
(gasoline, kerosene, etc.). The products are not
designed for these liquids!
CAUTIon: Wear ear protectors!
In terms of the applicable laws and regulations, ear
protection must be worn if the sound pressure is
greater than 85 dB (A). The owner is responsible for
ensuring compliance with these regulations.

Transport and storage

Delivery

Transport

Tabla de contenido
loading

Tabla de contenido