Menus; File Menu; Edit Menu; Tools Menu - NEC SpectraView II Guia Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 267
39 | NEC SPECTRAVIEW II - USER'S GUIDE
• When enabled, the display's Metamerism setting (available on the OSD and in MultiProfiler) will impact the
correlation between color measurement values and the color control values shown. Turning off the Metamerism
setting will improve the correlation, but may impact the visual match between the display and standard color
gamut displays.
• Since performing an Update will use measurements from the connected calibration sensor, the results will
only be as good as the accuracy of the calibration sensor used.

Menus

File menu

Open Target... - opens a Target file. This is the same as clicking the Target Settings: Open button.
Save Target As... - saves the current Target Settings to a file. This is the same as clicking the Target Settings: Save
button.
Calibrate... - starts the display monitor calibration routine for the currently selected display using the currently selected
Target Settings. This is the same as clicking the Calibrate button.
Generate ICC Profile... - starts the process of creating an ICC/ColorSync monitor profile for the currently selected
display in its current state without calibrating.
Validate Calibration... - measures the current state of the display monitor and compares to the currently selected
Target in order to quickly determine if the current calibration is still accurate, or if the display should be recalibrated.
Open previous calibration.. - opens a previous Monitor Calibration Settings file. This is the same as clicking the
Calibration: Open button.

Edit menu

Preferences... - opens the Preferences dialog. (shown on the Application menu on macOS)
Display Configuration... - (Windows and Linux only) opens the Display Configuration dialog. This is the same as
clicking the Display: Configure button.
Target... - opens the Edit Calibration Target dialog.

Tools menu

Information Window... - opens the Information window.
Colorimeter Window... - opens the Colorimeter window.
Test Pattern - displays a variety of test patterns on the screen that can be used to evaluate the status of the monitor
calibration and performance. Click the left and right arrow buttons to select different test patterns, or use the [ and ]
keyboard keys. Select this menu again to turn off the test pattern, or click the X button.
Ambient Light Measurement... - opens the Ambient Light Measurement window and is used to measure the ambient
light of the viewing environment around the display monitor. This feature is only available when using sensors that
support this measuring ambient light.
Monitor Settings... - opens the Monitor Settings window and is used to access some settings on the display monitor.
Update Internal Calibration... - opens the Update Internal Calibration window and is used to update the internal
Tabla de contenido
loading

Tabla de contenido