Functions / System Configuration For Connection Via Options Card; Functions / System Configuration For Connection Via Analogue Port - Aastra 400 Serie Manual Del Sistema

Ocultar thumbs Ver también para 400 Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Prestaciones

Functions / system configuration for connection via options card

Tab. 343 Opening doors: Function
Function
Open door
Tab. 344 Opening doors: System configuration
Parameter
Open door
Door intercom system

Functions / system configuration for connection via analogue port

Tab. 345 Opening doors: Function
Function
Function code
Open door *74 <Call number of the user who is assigned an analogue terminal to whose port the door inter-
com system is connected>
Tab. 346 Opening doors: System configuration
Parameter
Open door
User
Door opener DTMF sequence
Tip:
Store the function code on a function key (I*74 call number)
Aastra Intelligent Net:
In an AIN an authorized user can actuate all the door openers of the con-
nected door intercom system, regardless of the node to which they are
connected.
Reference to Other Features
Features:
"Door bell", página 526
"Dial door intercom", página 529
528
Function code
*74 <Call number of the door intercom>
Parameter value
Yes
<Call number>
Parameter value
Yes
<Call number>
<DTMF sequence>
Scope / remarks
Necessary authorisation of the user who wants to
carry out the function.
The number is defined in the numbering plan.
Scope / remarks
Necessary authorisation of the user who wants to
carry out the function.
The number is defined in the numbering plan.
The DTMF sequence must match the door opener
sequence in the TFE. If necessary, one or more pau-
ses "P" can be entered before or within the
sequence. Each "P" represents a 1 s pause.
Example: PP1P2P3
Funciones y prestaciones del sistema a partir de R2.1
syd-0370/1.2 – R2.1 – 07.2012
Tabla de contenido
loading

Este manual también es adecuado para:

415430470

Tabla de contenido