The machine is temporarily not enabled to select
the programme requested. Perform a spin, then
repeat the request.
A 25
Programme not available.
A 31
Optimisation procedure (OPT) already launched
by another user.
A 51
Spin with automatic wheel clamping system open
or incorrect wheel clamping. Repeat the locking
operation.
A 52
Hub mounting/demounting procedure started
automatic wheel clamping system. The procedure
stops automatically after 30 seconds. Press the
Stop button to interrupt the procedure.
A 60
Incorrect rim spoke storage procedure.
Carefully follow the instructions on the screen or
those in the Hidden weight section.
A 61
Incorrect automatic wheel width measurement.
Repeat the spin with automatic dimension acqui-
sition. If the problem persists, enter the correct
rim width value manually.
A 62
Incorrect automatic wheel width measurement.
Repeat the spin with automatic dimension acqui-
sition. If the problem persists, enter the correct
rim width value manually.
A 63
Incorrectly measured wheel dimensions. Repeat
the spin. If the error persists, set the dimensions
manually.
A 64
Incorrect plane acquisition point setting. Repeat
manual positioning of planes.
A 65
Wheel dimensions error. Repeat the spin. If the
error persists, set the dimensions manually.
A 66
Obstacle detected or wheel diameter less than
10" during internal measuring sensor move-
ment. Repeat the spin or insert the dimensions
manually.
A 99
Incorrect calibration phase. Repeat the spin, fol-
lowing the procedure described in this manual.
A Stp
Wheel stop during the spin phase.
A Cr
Spin performed with the guard raised. Lower the
guard to perform the spin.
74
– E – Error Messages
E 1
Error condition on unbalance sensitivity
calibration. Perform the sensitivity calibration
procedure.
E 2
Error condition on sensitivity calibration.
Repeat the sensitivity calibration, paying attention
to the first spin, which must be performed with the
wheel like the subsequent spins.
Take particular care NOT to knock the machine
during calibration.
E 3 I/E 2/3
Error condition at the end of sensitivity cali-
bration.
Repeat the calibration, if the message persists
perform the following checks:
• Correct sensitivity calibration procedure;
• Correct fastening and position of the calibration
weight;
• Mechanical and geometric condition of the
calibration weight;
• Geometry of the wheel used.
E 6
Error condition when executing optimisation
programme. Repeat the procedure from the
beginning.
E 8
Printer out of service or not connected.
E 10
Internal measuring sensor not in the rest position.
E 11
Internal measuring sensor motor steps coun-
ting error.
E 12
External measuring sensor not in the rest position.
E 13
External measuring sensor motor steps coun-
ting error.
E 27
Excessive braking time. If the problem persists,
call in the technical support centre.
E 28
Encoder counting error. If the error occurs fre-
quently, call the technical support centre.
E 30
Spin device failure. Switch off the machine and
call in the technical support centre.
E 32
The wheel balancer was jolted during the reading
phase. Repeat the spin.
E 50
Automatic wheel clamping system failure.
Restart the wheel balancer.
If the error persists, request servicing.
EYE LIGHT - Operator's manual