The settings recommended in the chart are to be used if no settings for "Normal level",
"Lower level", "Tank empty" and high water level were made in the factory.
Settings used for initial operation are to be entered in the chart by hand.
Menu items
(top line)
Normal level
Lower level
Tank empty
High water level
4.3 Grease Separator Remote Control
Overview of the remote control,
Button
Symbols and their meaning
Process steps:
Emergency-off switch
Recommended setting
Height of pipe bottom discharge
25 cm below the normal level
5 cm
30 cm above the normal level
page 2
LED lights up: Disposal/cleaning program in operation
Suction pump (suction vehicle):
LED ON flashes: Signal for suction pump switch-on
LED OFF lights up: Signal for suction pump switch-off
LED lights up: Disposal/cleaning program completed
Disconnect the suction hose (suction vehicle) from the
disposal pipe
LED lights up: Fault has occurred
Start disposal/cleaning program: Turn the key switch into position
and hold for approx. 1 second
Complete disposal/cleaning program: Turn the key switch into
position and hold for approx. 3 seconds
Setting for
initial operation
D
.
Grease Separator
Operation
57