SERVICE
GB
HYDRAULIC OIL AND FILTERS (every 400 hours)
1. Drain Oil reservoir by removing drain plug H on
bottom of hydraulic oil reservoir.
2. Ensure that plug is clean and reinstall in tank.
3. Unscrew both filter elements G and discard.
4. Clean the rubber seal through which the filter
elements pass.
5. Apply a thin film of oil to the seals of the new
filters and install.
6. Remove plug K and add the recommended oil
(see below) until the indicator on the oil level
gauge J is centered in the green area of the
gauge. Avoid operation in either red zone as
insufficient oil could damage hydraulic compo-
nents. Too much oil could lead to oil overflow-
ing the reservoir as it heats up.
7. Reinstall plug K.
8. Start the tractor and allow to run at 1/4 throttle
for approximately 5 minutes.
9. Allow oil to cool and recheck the oil level and
adjust as required.
Hydraulic oil type requirements:
Shell Harvella
SAE 10W30
JACOBSEN HR9510
SAFETY & OPERATION MANUAL