Calibrate Oil And Dye Inject Scales; Calibrate Oil Drain Scale - Beissbarth BAC 4100a Instrucciones Originales

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 128
Maintenance

Calibrate Oil and Dye Inject Scales

1. Remove the dye inject and oil inject bottles from their
scales. See Figure 21.
2. Select CALIBRATE OIL INJECT 1 from the Setup
menu.
3. When prompted for the first weight, accept
as the default, and press OK .
4. When prompted for the second weight, attach the
calibration weight supplied with the machine to the
magnetic connector for the Oil Inject 1 scale.
5. Program
533 GRAMS
and press OK .
6. When prompted that the calibration is complete,
press OK to exit.
7. Repeat this procedure for the other two load scales
by selecting CALIBRATE OIL INJECT 2 and
CALIBRATE UV DYE INJECT from the Setup menu.

Calibrate Oil Drain Scale

1. Remove the oil drain bottle from the scale.
2. Hook the notch in the end of the oil drain calibration
bracket (supplied) around the oil drain inlet fitting as
shown in Figure 22.
3. Select CALIBRATE OIL DRAIN from the Setup
menu.
4. When prompted for the first weight, enter
53 GRAMS
as the default, and press OK .
5. When prompted for the second weight, place the
calibration weight supplied with the unit on the
bracket as shown, and enter the following value :
586 GRAMS
6. When prompted that the calibration is complete,
press OK to exit.
7. Remove the calibration weight and bracket, and
replace the oil drain bottle.
32
0 GRAMS
Oil Inject
Bottle 1
(white cover)
Oil Inject
Bottle 2
(green color
on cover)
UV Dye
Inject Bottle
(yellow color
on cover)
Figure 21
Oil Drain
Inlet Fitting
Figure 22
Magnetic Couplers
Oil Drain
Calibration
Bracket and
Weight
loading