Maintenance
Tank Filling
This menu item is used to transfer refrigerant from a
source tank to the ISV.
1. Connect the low-side (blue) hose to the liquid
connector on a full source tank.
2. Position the source tank in such a way that liquid
refrigerant is supplied to the connection. Open the
source tank valve.
3. Select TANK FILLING from the Setup Menu. The
machine displays
FILL AMOUNT (KG)
CONNECT LOW SIDE HOSE
TO SOURCE TANK
OK TO CONTINUE ESC TO QUIT
4. Enter the quantity to recover, and press OK. Add
at least 3.6 kg of refrigerant to ensure enough is
available for charging.
5. The machine begins filling the internal storage
vessel (ISV) and automatically stops when the
preset tank fill level is reached. To stop the tank fill
before the preset level is reached, select ESC .
6. Close the valve and remove the hose from the
source tank.
26
XX.XXX