Tank Filling
1. The machine displays,
ENTER THE QUANTITY TO BE RECOVERED
MAX. RECOVERABLE QUANTITY
QUANTITY TO RECOVER
Connect the low-side (blue) hose to the liquid
connector on the source tank.
2. Open the coupler valve on the hose by turning the
collar clockwise. Open the source tank valve.
3. Position the source tank in such a way that liquid
refrigerant is supplied to the connection.
4. Press OK. The machine begins filling the internal
storage vessel (ISV). Add at least 3.6 kg of
refrigerant to ensure enough is available for
charging. This process takes 15–20 minutes.
5. The machine stops when the designated amount of
refrigerant has been transferred to the ISV, or when
the source tank is empty. Follow the messages on
the display screen.
6. Close the coupler valves by turning the collars
counterclockwise.
7. Press OK to return to the Setup Menu.
The machine is ready for operation.
Note:
•
There is no need to calibrate the scale; it is
calibrated at the factory.
•
After the tank fill process is complete, the
display does not show the same amount as the
programmed fill level.
The display shows the amount of refrigerant that
is available for charging, which is approximately
0.91 kg less than the total amount of refrigerant in
the tank.
BAC 4100a Rev. A
XX.XX KG
0000 GR
Setup
13