Setup Menu Functions
Access the following functions by pressing the Menu key and selecting Setup.
Air Purge Info
Displays internal storage vessel (ISV) pressure
and temperature. Use to check ISV for excessive
pressure.
Backlight
Adjusts the contrast on the display screen.
Beeper Setting
Turns the audio "beep" OFF and ON.
Calibrate Oil Drain
User calibration of oil drain scale using the
supplied calibration weight. Refer to Calibrate Oil
Drain in the Maintenance section.
Calibrate Oil Inject 1
User calibration of oil injection scale number one
using either the supplied calibration weight or a
user-provided weight. Refer to Calibrate Oil and
Dye Inject Scales in the Maintenance section.
Calibrate Oil Inject 2
User calibration of oil injection scale number two
using either the supplied calibration weight or a
user-provided weight. Refer to Calibrate Oil and
Dye Inject Scales in the Maintenance section.
Calibrate UV Dye Inject
User calibration of the UV dye scale using either
the supplied calibration weight or a user-provided
weight. Refer to Calibrate Oil and Dye Inject
Scales in the Maintenance section.
Calibration Check
Use to verify internal scale calibration. Refer to
Calibration Check in the Maintenance section.
Change Vacuum Pump Oil
Displays how long the vacuum pump has
operated since the last oil change, and the
amount of time remaining until the next oil
change is needed. For maximum vacuum pump
performance, change vacuum pump oil every
time the filter is replaced. Refer to the Change
Vacuum Pump Oil in the Maintenance section.
BAC 4100a Rev. A
Introduction
Date and Time Setup
Program the machine for current date and time.
Filter Change
The filter removes acid, particulates, and moisture
from the refrigerant. To meet requirements, it
is mandatory to replace the filter after 150 kg
(331 lbs.) of refrigerant has been filtered.
This menu item displays the filter capacity
remaining until the machine locks down and no
longer functions. Refer to Filter Change in the
Maintenance section.
Garage Data
Programs information that will appear on the
printout each time the print function is used.
Hose Flush
Flushes residual oil from the machine to prepare
for the service of next vehicle.
Language Selection
Select a language for screen prompts. English is
the default language.
Refrigerant Management
Displays the amount of refrigerant recovered,
charged, and replenished (for the life of the
machine), and filtered since the last filter change.
Service
For Beissbarth service center use only.
Tank Fill Adjustment
The tank fill value may be adjusted up or down
to suit the user's needs. The default is 6.1 kg
(13.4 lbs.). Refer to Tank Fill Adjustment in the
Maintenance section.
Tank Filling
Transfer refrigerant from the source tank to the
ISV. Refer to Tank Filling in the Maintenance
section.
Unit of Measure
Program the machine to display units of measure
in kilograms or pounds. The default display is
kilograms.
9