Calibration Check

This function is used to ensure the machine's internal
scale is always calibrated. During this test, use only the
calibration weight that is provided with the machine.
1. Select CALIBRATION CHECK in the Setup menu.
The machine displays
PLACE SAMPLE WEIGHT ON SCALE
PRESS OK TO TEST PRESS ESC TO QUIT
2. Refer to Figure 18, and verify the magnet on the
bottom of the machine is clean.
3. Attach the calibration weight to the magnet on the
bottom of the machine. Select OK .
If the display shows
PROCEDURE COMPLETED
the scale is in calibration. Select OK .
If the display shows
CALIBRATION REJECTED!
the scale is out of calibration. Contact an authorized
Beissbarth service center for assistance.
4. Remove the calibration weight from the scale.
BAC 4100a Rev. A
Maintenance
Magnet
Figure 18