Operating Instructions — Automatic
Automatic Function
The AUTOMATIC function allows a user to program an
automatic recovery, vacuum, and / or charge sequence.
The user may choose to skip any step in the automatic
operation during the programming. A total automatic
sequence may take up to an hour to complete.
1. Connect high-side (red) and low-side (blue) service
hoses to the A/C system, and open coupler valves.
2. Press AUTOMATIC. The machine displays
1
2
3
4
5
Refrigerant
6
7
8
Extra Oil (2)
3. Use the number keys on the keypad to make
selections 1–3 for the vehicle's A/C system. For
selections 4–8, enter a value and press OK .
4. The display shows an overview of the functions,
with the selected functions highlighted. Select
OK to start.
5. Follow instructions on the display. The unit pauses
before oil injection to give the user time to confirm oil
quantity. After five seconds, the Automatic sequence
begins.
6. When the sequence is complete, close the high-side
(red) and low-side (blue) coupler valves.
7. When prompted, remove the service hoses from the
A/C system, and install the hoses on the machine's
storage ports.
8. Select OK to begin clearing hoses. This prepares the
machine for the next service.
20
HP
LP
HP + LP
UV Dye
Vacuum
Extra Oil
WARNING: To prevent personal
injury while working with refrigerant,
read and follow the instructions
and warnings in this manual, and
wear protective equipment such as
goggles and gloves.