3.3 - ELECTRIC CONNECTION

DANGER
• The power feed line should be provided
with a suitable omni-polar DISCONNECT-
ING SWITCH (automatic thermo-magnetic
switch or differential) placed before the
control unit main switch, with a minimum
contact opening of 3 mm.
• The earthing system should comply with
the local electric regulations in force.
• The electric power cables should comply
with the maximum current required by
the machine.
• The specifications of the electric power
line should correspond to the specifica-
tions of the identification plate and to
those mentioned in the technical speci-
fications table that can be consulted in
the first part of this booklet.
DANGER
Before connecting the machine to the
electric line, make sure that the DISCON-
NECTING SWITCH is disconnected (line
not energized).
IMPORTANT
The disconnecting switch placed in the upper
part of the oven shall be easily to be reached.
DANGER
In case of two- and three-chamber ovens,
each oven shall be connected with a special
knife switch, it is not possible to connect
more than one oven to one knife switch.
3.3.a - Electrically connecting the oven (Fig. 5)
Remove the cover (1) by undoing the screws (2).
Run the power cable through the cable duct (3) and
connect it to the terminal board (4).
Connect the phases to terminals L1, L2 and L3, the
neutral to terminal N and the earth to terminal T.
For areas where an automatic load distributor is pre-
sent, connect the two 12V power wires to the "SAFE"
terminals.
Refit the cover (1).
EN - 14
TL 105 - TL 108
Installation and connections
4
3
L3 L2 L1 N
FIG. 5
1
2