3.3 - ELECTRIC CONNECTION
DANGER
• The power feed line should be provided
with a suitable omni-polar DISCONNECT-
ING SWITCH (automatic thermo-magnetic
switch or differential) placed before the
control unit main switch, with a minimum
contact opening of 3 mm.
• The earthing system should comply with
the local electric regulations in force.
• The electric power cables should comply
with the maximum current required by
the machine.
• The specifications of the electric power
line should correspond to the specifica-
tions of the identification plate and to
those mentioned in the technical speci-
fications table that can be consulted in
the first part of this booklet.
DANGER
Before connecting the machine to the
electric line, make sure that the DISCON-
NECTING SWITCH is disconnected (line
not energized).
IMPORTANT
The disconnecting switch placed in the upper
part of the oven shall be easily to be reached.
DANGER
In case of two- and three-chamber ovens,
each oven shall be connected with a special
knife switch, it is not possible to connect
more than one oven to one knife switch.
3.3.a - Electrically connecting the oven (Fig. 5)
•
Remove the cover (1) by undoing the screws (2).
•
Run the power cable through the cable duct (3) and
connect it to the terminal board (4).
•
Connect the phases to terminals L1, L2 and L3, the
neutral to terminal N and the earth to terminal T.
•
For areas where an automatic load distributor is pre-
sent, connect the two 12V power wires to the "SAFE"
terminals.
•
Refit the cover (1).
EN - 14
TL 105 - TL 108
Installation and connections
4
3
L3 L2 L1 N
FIG. 5
1
2