MILLENNIUM MM/MB
General specifications and warning
1.5 - PREARRANGEMENTS AT PURCHASER'S
CHARGE
a) Prearrangement of the installation place.
•
The supporting surface the oven shall be placed on
shall have the features as reported in "Installation"
chapter.
b) Electric prearrangement.
•
The power system should comply with the local
regulations and provided with an efficient earthing.
•
An omnipolar sectioning device shall be positioned
on the power supply line at the upper side of the oven.
•
The electric power supply cables shall be
dimensioned by considering the highest
power rate needed by the oven, so that a total
voltage drop is lower than 2 %, under full load
conditions.
c) Flue prearrangement
•
It is necessary to prearrange a vapour flue, whose
features shall be in compliance with the rules being
in force in the Country the oven shall be installed in.
b) Neutral wire
•
The machine is equipped with neutral wire, therefore,
a special terminal being identified according to the
relevant directions has been prearranged.
1.6 - EMERGENCY OPERATIONS IN CASE OF
FIRE
a) In case of fire, disconnect the oven by disconnecting
the cutout switch.
b) Put out the fire by means of suitable fire extinguishers.
DANGER
When the oven is under tension, do not try to
extinguish the fire by using water.
1.7 - EXPLOSION RISK
•
The oven is not suitable for being utilized in hazardous
environment.
1.8 - ACOUSTIC PRESSURE LEVEL
With MILLENNIUM ovens, an A acoustic continuous
equivalent weighted pressure level(dB) under the
maximum allowed 70dB level is kept.