3.3 - ELECTRICAL CONNECTION (Fig. 6)
The power feed line should be provided with a
suitable omnipolar DISCONNECTING SWITCH
(automatic thermomagnetic switch or differential)
placed before the control unit main switch, with
a minimum contact opening of 3 mm.
The earthing system should comply with the local
electric regulations in force.
Electric power supply cables shall be
dimensioned depending on the highest power
rate being needed by the oven and in such a way
that the total voltage drop is lower than 2 %, under
full load conditions.
The specifications of the electric power line
should correspond to the specifications of the
identification plate and to those mentioned in the
technical specifications table that can be
consulted in the first part of this booklet.
Before connecting the machine with the electric line,
make sure that the DISCONNECTING SWITCH is
disconnected (line not energized).
3.3.a - Electric oven connection
• To reach the electric oven part, remove the lateral right-
hand panel (1).
• Connect a suitably dimensioned electric cable (2) with
the terminal (3) according to the oven absorption, the
three phases shall be connected with F1-F2-F3
terminals, the neutral wire with N terminal, the earth
with T terminal.
• Insert the electric cable (2) in the special fairlead (4)
and connect it with the disconnecting switch placed in
the upper part of the oven.
The disconnecting switch placed in the upper part of
the oven shall be easily to be reached.
• Re-install the lateral right-hand panel (1).
In case of two- and three-chamber ovens, each oven
shall be connected with a special knife switch, it is
not possible to connect more than one oven to one
knife switch.
Concerning 835/D-E, two-chamber models, there is
only one electric connection cable for both
chambers.
Concerning 12.35/D-E, there is two electric
connection cable for each chambers.