Technical data
15
Technical data
General data
Description
Max. metering capacity [l/h]
Min. metering capacity [ml/h]
Max. metering back-pressure [MPa (bar)]
Max. metering frequency [1/min]
2)
Dosage rate/stroke [ml] at max. metering frequency
Reproduction accuracy [%]
Max. conveyable viscosity
[mPas] with valves:
Permissible ambient
temperature [°C]
Max. suction height [mWs]
Viscosity:
Max. suction tube length [m]
Viscosity:
Max. suction side pre-pressure [MPa (bar)]
Min. differential pressure on suction/pressure side
[MPa (bar)]
Min. hose Ø [mm] suction side;
viscosity:
Min. hose Ø [mm] pressure
side; viscosity:
Noise level [DBA] at a 1 m distance
(according to DIN EN 12639/ EN ISO 9614-2)
Weight [kg]
Approvals
1) Values calculated using water as a metering medium at a temperature of 20 °C.
2) Values vary depending on calibration.
3) Suction heights determined with clean, moistened valves at maximum stroke frequency.
4) Measurement in the MK240 heating cabinet.
MAN046939 Rev. 6-10.2021
Dosing mode
Dosing mode
1)
Dosing mode
Dosing mode
Dosing mode
Dosing mode
Dosing mode
Dosing mode
Standard
Spring-loaded with
metering mode
Spring-loaded with
metering mode
3)
up to 50 mPas
3)
over 50 mPas
up to 50 mPas
over 50 mPas
up to 50 mPas
over 50 mPas
up to 50 mPas
over 50 mPas
Type
Type
00510X
01110S
5
11
4,2
9,2
3,3
7,3
0,5 - 5
1 - 11
0,1 (10)
176
170
147
142
117
135
18 - 176
17 - 170
2)
0,47
1,08
200
500
1000
2 - 45
0,2 (2)
0,1 (1)
5
4
9
5
5
6
3,1
188
Type
Type
Type
03003M
05010M
12003M
30
50
120
25
41,7
100
20
33,3
80
3 - 30
5 - 50
12 - 120
0,01
0,03 (3)
1 (10)
0,03 (3)
162
135
108
16 - 162
3,08
5,14
12,33
< ± 3
100
200
100
250
500
250
500
1000
500
2
1
3
2
0,1 (1)
0,2 (2)
0,1 (1)
0,05 (0,5)
0,1 (1)
0,05 (0,5)
6
12
12
19
6
9
12
< 60
3,8
5,2
5,7
CE
9