Control/software
Dosing monitoring
When the "Dosing monitoring" function is activated, an alarm is shown in the pump
display if the flow rate falls below an adjustable limit value. You can also specify whether
the pump is stopped when an alarm occurs or continues running. Note: The "Dosing
monitoring" menu item can only be selected if an oval gear meter is connected to the input
provided for this purpose
Ä Chapter 7.2.2 'Electrical installation' on page 49 ).
(see
10
Factory setting: Without dosing monitoring
Select [Dosing monitoring]:
1.
[Call the Main menu]:
2.
[Select Configuration]:
3.
Use the scrollbar to scroll to the [Oval gear meter] menu item.
4.
[Select Oval gear meter]
ð The screen switches to the [Oval gear meter] selection.
5.
[Select Dosing monitoring]
ð The screen switches to the [Dosing monitoring] selection.
6.
If required, select the selection box 'With dosing monitoring' .
7.
[Press the Next button]
ð Screen change: 'Dosing monitoring' / 'Stop pump' / 'Quantity' .
8.
If required, select the 'Stop pump' selection box.
9.
[ Press the Next button]
ð The screen changes to the setting: 'Dosing monitoring' / 'Monitoring time' .
10. Use the slider to enter the minutes before the decimal point.
11. Select the seconds after the decimal point.
12. Use the slider to enter the seconds.
13. [ Press the Next button]
ð The screen changes to the setting: 'Dosing monitoring' / 'Deviation' .
14. Use the slider to enter the deviation in percent (%).
15. Press the
ð Save and screen change to the configuration overview.
16. Press the
17. Press the
MAN046939 Rev. 6-10.2021
3
4
11
12
Ä Chapter 8.5 'Main menu' on page 63
Ä Chapter 8.8 'Configuration' on page 89
.
.
.
button.
button to return to the [Main menu].
button to return to the [Operating display].
5
6
13
116
7
9
8
15
14