Assembly and connection
Wall mounting
Fig. 10: Preparations for wall mounting
For wall mounting, use fastening elements with the code 1 ( Fig. 10 , item 2)
and 2 ( Fig. 10 , item).
1.
Turn the mounting plate over.
2.
Insert fastening elements (code 1, Fig. 10 , item 2) into the two upper "wall" openings
(for wall mounting)from behind and engage into position.
3.
Insert fastening elements (code 2, Fig. 10 , item 3 ) into the two lower "wall"
openings from behind and engage into position.
4.
Turn the mounting plate over again and hold it against the required mounting
position.
5.
Use the mounting plate as a template and mark the required boreholes ( Fig. 10 ,
item 5) using a sharp pencil.
6.
Drill the holes.
7.
Fasten the mounting plate securely to the wall.
8.
Place the pump onto the hooks on the mounting plate from above.
9.
Slide the pump downwards onto the mounting plate until it engages with an audible
click.
10.
11. Attach the connecting lines (hydraulic and electric):
Ä Chapter 7.2.1 'Hydraulic installation' on page 43
Ä Chapter 7.2.2 'Electrical installation' on page 49 .
MAN046939 Rev. 6-10.2021
2
1
3
The hooks of the fastening elements must point upwards.
To remove the pump from the mounting plate again, push down on the
fixing tab ( Fig. 10 , item 6).
5
5
4
5
5
6
42
9
8