4. Using the envisaged control and stop devices (key-operated
selector switch, control pushbuttons or radio transmitters),
perform tests of opening, closing and stopping the door and
ensure that operations correspond to specifications.
5. Test several times to assess smooth operation of the door and
check for any defects in assembly or adjustment and any possi-
ble points of friction.
6. Check operation of all system safety devices one at a time (pho-
tocells, sensitive edges, emergency stop, etc.); in particular, each
time a device is activated the "OK" led on the control unit must
flash rapidly twice to confirm acknowledgement of the event.
7. To check the photocells, and to ensure there is no interference
with other devices, pass a cylinder with diameter of 5cm and
length 30cm on the optical axis, first close to the TX, then close
to the RX and lastly at the centre between the two and ensure
that in all cases the device engages, changing from the active
status to alarm status and vice versa. Lastly ensure that the envi-
saged action is generated on the control unit, for example: in the
closing manoeuvre it inverts movement.

5.2) Commissioning

Commissioning can only be performed after positive results of all test
phases on TEN and the other devices present. Partial or "makeshift"
commissioning is strictly prohibited.
1. The prepared automation technical documentation should be
conserved for at least ten years and must contain at least the fol-
lowing: overall drawing of the automation, electrical wiring dia-
gram, risk assessment and relative solutions adopted, manufac-
turer's declaration of conformity for all devices used (in the case
of TEN, use the EC declaration of conformity enclosed); copy of
the operation instruction manual and maintenance schedule for
the automation.
2. Affix a dataplate on the door, specifying at least the following
data: type of automation, name and address of manufacturer
(responsible for commissioning), serial number, year of construc-
tion and CE mark
3. Permanently affix a label or plate in the vicinity of the door, indi-
cating the operations for door release and manual manoeuvres.
4. Permanently affix a label or plate on the door, bearing this image
(min. height 60 mm). (Figure 23)
5. Prepare and provide the owner with the declaration of conformi-
ty of the automation.
6. Prepare and provide the owner with the manual "Automation
operation instructions and warnings".
8. If hazardous situations generated by the moving barrier are pro-
tected by means of impact force limitation, measure the force as
specified in the standard EN 12445. If speed and motor force
controls are used as auxiliary functions with the system for reduc-
tion of impact force, test and identify the setting that obtains the
best results.
7. Prepare and provide the owner with the automation maintenance
schedule (containing all prescriptions for maintenance of individ-
ual devices)
8. Before commissioning the automation, ensure that the owner is
adequately informed in writing (such as in the automation instruc-
tion and warning manual) of all associated risks and hazards.
23