For connection of an optical device type OPTO SENSOR make the
connections as shown in Figure 26. The maximum current supplied
on the 12Vdc line is 40mA.
7.3.3) Photocells
The "BlueBUS" system enables, by means of address assignment using the specific jumpers, recognition of the photocells by the control unit
and assignment of the correct detection function. The address assignment procedure is performed both on the TX and RX (setting the
jumpers in the same way) and ensuring that there are no other pairs of photocells with the same address.
In an automation for up-and-over doors with TEN photocells can be installed as shown in Figure 27. After installing or removing photocells
the learning phase must be repeated on the control unit as described in the paragraph "4.2 Learning devices".
27
Table 14: Photocell addresses
Photocell
PHOTO
Photocell h = 50
With activation on closure
PHOTO II
Photocell h = 100
With activation on closure
PHOTO 1
Photocell h = 50
With activation on closure and opening
PHOTO 1 II
Photocell h = 100
With activation on closure and opening
7.3.4) MOTB digital selector and proximity reader for MOMB transponder badges
BlueBUS can be connected to up to 4 digital MOTB selectors or MOMB type transponder badge readers.
MOTB enables control of the automation after entering a valid numerical code that has been previously memorised.
MOMB enables control of the automation by moving a valid transponder badge that has been previously memorised.
These devices are equipped with an individual ID code and are recognised by the control unit only after being memorised, which is performed
during the device acquisition phase. This prevents any unauthorised attempt to replace the device and inhibits control of the automation. For
further information see the specific instruction manuals for MOTB and MOMB.
26
Jumpers
Photocell
PHOTO 2
Photocell
With activation on opening
PHOTO 2 II
Photocell
With activation on opening
PHOTO 3
CONFIGURATION NOT ADMITTED
GB
Jumpers
21