Item
Description
...V = The input trigger level (Table 4) or the
5.0V
output amplitude (Table 5).
22.
, ...,
23.
The measured values applicable to the task
13.400
selections in Item 25, area and + the
55mA
measurement range and units.
24.
A soft-key function. To select an available
function, press the soft-key below it. Example:
Sk1/2
= Move left
= Move right
25.
The task selection menu. One task selection is
permitted in each area ( and ).
= cursor position (flashes on/off)
= a button or task selection is set in area or
.
Sets the Dual Function, area selections to
off. This saves the battery power.
Refer to: Table 2 & Table 3.
Help: Shows a connection diagram for the task
selections you have set.
Set Up: Shows the Set Up menu to set up the
basic operation. Refer to Table 1.
OK: Accepts the selections on the menu.
Note: MENU/OK also does this.
Utilities: Leak Test. Use this function with a
UPM. Refer to Figure 13.
Snapshot: Optional item - To use this facility,
install the data logging upgrade kit. Refer to
the user manual - K0397: DPI800 series data
logging upgrade kit.
1.3 Prepare the Instrument
Before you use the instrument for the first time:
•
Make sure that there is no damage to the instrument,
and that there are no missing items.
•
Remove the plastic film that protects the display. Use
the tag () in the top right-hand corner.
•
Install the batteries (refer to Figure B1). Then re-attach
the cover.
1.4 Power On or Off
To set the power on or off, press (Figure A1 - Item 1).
The instrument does a self test and then shows the
applicable data.
When the power is off, the last set of configuration options
stays in memory. Refer to "Maintenance".
= Output operation (Table 5).
1.5 Set up the Basic Operation
Use the Set Up menu to set up the basic operation of the
instrument.
Task selection
1
2
menu:
MENU
OK
+
(Table 2)
If there is additional data for a menu option, select Settings
() to see the values that are set up. If necessary, adjust
the values.
Table 1: Menu Options - Set Up
Options
Description
To select the applicable international
... Scale
temperature scale: IPTS 68 or ITS 90.
To add a 250Ω series resistor into the mA circuit.
You can then use this instrument together with a
HART® communicator to set up and calibrate
HART® devices.
To select and set up the backlight facility + timer.
Additional data: Select Settings ()
To select and set up the power off facility + timer.
Additional data: Select Settings ()
To show the battery level (%).
To set the display contrast (%).
Increases %, decreases %
To set the time + date. The calibration facility
uses the date to give service and calibration
messages.
To set the language option.
To calibrate the instrument.
Additional data: Refer to "Calibration".
To select and show the applicable status data.
(Software Build, Calibration Due date, Serial
Number, IDOS Information).
1.6 Select a Task (Measure and/or Supply)
When the instrument is set up (Table 1), use the task
selection menu to select the applicable task.
1
Task selection menu:
MENU
OK
1
2
(Table 2 & Table 3)
Menu:
3
4
Set Up
MENU
OK
(Table 1)
2
3
4
MENU
MENU
+
+
OK
Task = mA output
Copyright 2005 Baker Hughes Company.
English–DPI880 Instruction Manual | 3
5
MENU
OK
[]/[ ]
5