Dometic Marine Climate System MCS10 Instrucciones De Montaje página 17

Ocultar thumbs Ver también para Marine Climate System MCS10:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 85
MCS5, MCS10, MCS15
8.1
Spacing Allowances and Unit Dimensions
Key to fig. 2, page 3:
Item
1
2
3
4
5
6
7
8
9
10
11
12
I
NOTE
The blower and duct ring can be positioned either vertically or
horizontally; fig. 2, page 3 shows a Marine Climate System MCS5 with
blower rotated to vertical position.
Space allowances (fig. 2, page 3)
The following space allowances should be considered when mounting
the unit:
 Allow a minimum of 152 mm around the perimeter of the unit in the
area of the seawater and condensate drain piping (1).
 Allow a minimum of 76 mm of air space in front of the evaporator coil
for the return-air intake if it is adjacent to a bulkhead (2).
 For flexible ducting connection (10) and for clearance needed behind
the supply-air grille
– allow 51 mm for the duct ring,
– allow 25 mm for the duct bend radius and
– add diameter of the ducting to get the total clearance distance.
 Allocate enough space for installation and serviceability.
EN
Description
Space allowance for return-air intake
(if adjacent to bulkhead)
Space allowance for seawater piping
Evaporator and condenser coil
Duct ring
Electric box
Rotary compressor
Refrigent connection
(allow space for access)
Seawater in
Seawater out
Total minimum clearance
Standard blower position as shipped
Possible drain position
Installation
17
loading

Este manual también es adecuado para:

Marine climate system mcs5Marine climate system mcs15