Descaling
When the flow is reduced, the water purifier should be descaled
to extend its lifetime. When the flow cannot be restored despite
descaling and filter replacement, contact your dealer. During
the descaling procedure, which takes around 10 hours, the
water purifier cannot be used.
The descaling product can be ordered from your dealer, see
«Consumables».
The descaling product must be kept out of the
reach of children! Wash your hands after using it.
1.
Check that the water purifier is in standby mode.
2.
Press the service button, using a pen, until the
service light comes on. Release the button. The light
on the faucet now flashes rapidly for 15 seconds.
This will prevent flushing from taking place during
descaling.
3.
Unscrew the filter container in accordance with
«Replacing the filter», points 2 - 5. Remove the filter
and put it a side.
4.
Mix 50 g (approx. 1/4 of the bag) of the descaling
product with 7 dl of lukewarm water. Stir until the
powder has dissolved, see fig. A.
5.
Screw the filled container in place.
6.
Start the water purifier and produce pure water for
30 seconds.
7.
While production is still in progress, pull out the
plug, see fig. B.
8.
Allow the water purifier to stand for approx. 10
hours (e.g. overnight).
9.
Undo the container and empty the water. Replace
the filter in accordance with «Replacing the filter»,
points 7 - 8, except that the previously used filter is
used here.
10.
Close the front cover and connect the plug.
11.
Flush the water purifier in accordance with «Flush-
ing».
Do not use the purified water until flushing is
complete.
The descaling process is now finished. The water
purifier is ready to be used.