Checking And Regulating The Safety Microswitches; Safety Microswitches Replacement - Silca Tri-Code Manual De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operating manual - English
7.10
C
HECKING AND REGULATING THE SAFETY MICROSWITCHES
1) Remove the back panel (Ch. 7.7, page 76).
2) check the connecting wires on the two microswitches (C1 - fig. 70).
3) carry out test 11 (Ch. 5.7.2, page 48) to check that proper contact is made.
If this is not so, check that the cam (S) causes the two microswitches to click. If necessary, regulate
the cam as follows:
4) loosen the two screws (L2) and remove the microswitch plate; lower the protective shield (V).
5) use the 2,5mm (0.0983") T wrench to loosen the grub screw (S1 - fig. 70).
6) turn the cam (S) until the microswitches click, with the microswitch plate installed.
Fig. 70
7.11
S
AFETY MICROSWITCHES REPLACEMENT
1) Remove the back panel (Ch. 7.7, page 76).
2) loosen the two screws (L2) and remove the microswitch plate (fig. 70).
3) disconnect the wiring between the two microswitches (C1) (fig. 70).
4) loosen the two nuts (D1) (fig. 71) and replace the faulty part.
5) fix the microswitches with the two nuts and re-connect the two connection wires (grey wire towards
the motor, black wire towards the gas spring).
6) replace the microswitch plate with the screws (L2) without exerting pressure.
7) adjust the position of the microswitch plate until you hear the microswitches click when the protective
shield is moved.
8) secure the microswitch plate by tightening the screws (L2).
Fig. 71
C1
L2
Copyright Silca 2006
S
S1
D1
TRI-CODE H.S.