Note: from here on consult this manual for every operation required on the display. Press ENTER; the display will
show the message:
- Raise the safety shield.
- Turn the cutter spindle by hand in order to reach the tool-locking grub screw (E1).
- with one hand hold the cutter to be removed and with the other use a 2.5mm (0.0983") hex wrench
to loosen the grub screw (E1) (fig. 48).
- remove the tool.
- fit the U111 tracer point into the spindle (fig. 49) pushing all the way in.
- hold the U111 tracer point still with one hand and with the other tighten the grub screw (E1) with the
2.5mm (0.0983") hex wrench.
E1
cutter
H101
Fig. 48
Press ENTER; the display will show the message:
- Loosen the (F1) handle by one turn and pull the anatomic grip (F2) towards the operator. This
releases the clamp so that it can slide to the right. Release the anatomic grip, move the clamp
manually and the positioning device will lock the clamp into the reference notch.
- When the clamp is in position (Clamp A) tighten the (F1) handle.
- Turn the (F) knob to the left. Fit the Z21 template (fig. 50) into jaw A with the wording "Z21" upwards
so that the operator can read it. Make sure it lies flat on the clamp and is right up against Stop 2 (to
do this turn the Stop 1 plate to the left and downwards).
- Secure the Z21 template by turning the (F) knob to the right.
Fig. 50
I n s t a l l
U 11 1 t r a c e r
S e e o p e r a t i n g m a n u a l .
[ E N T E R ]
tracer point
U111
I n s t a l l
c l a m p A a n d
Z 2 1 t e m p l a t e
[ E N T E R ]